During startup a number of error codes may be presented. This document serves as a reference for tracing the problem.

height sensor

Errors are logged as "code @ position". Code is the status code as returned by the VL53L0X API, and position determines which API call during initialization failed. Test

Code Constant Description
-1 VL53L0X_ERROR_CALIBRATION_WARNING Warning invalid calibration data may be in used VL53L0X_InitData(), VL53L0X_GetOffsetCalibrationData, VL53L0X_SetOffsetCalibrationData
-2 VL53L0X_ERROR_MIN_CLIPPED Warning parameter passed was clipped to min before to be applied
-3 VL53L0X_ERROR_UNDEFINED Unqualified error
-4 VL53L0X_ERROR_INVALID_PARAMS Parameter passed is invalid or out of range
-5 VL53L0X_ERROR_NOT_SUPPORTED Function is not supported in current mode or configuration
-6 VL53L0X_ERROR_RANGE_ERROR Device report a ranging error interrupt status
-7 VL53L0X_ERROR_TIME_OUT Aborted due to time out
-8 VL53L0X_ERROR_MODE_NOT_SUPPORTED Asked mode is not supported by the device
-9 VL53L0X_ERROR_BUFFER_TOO_SMALL ...
-10 VL53L0X_ERROR_GPIO_NOT_EXISTING User tried to setup a non-existing GPIO pin
-11 VL53L0X_ERROR_GPIO_FUNCTIONALITY_NOT_SUPPORTED unsupported GPIO functionality
-12 VL53L0X_ERROR_INTERRUPT_NOT_CLEARED Error during interrupt clear
-20 VL53L0X_ERROR_CONTROL_INTERFACE error reported from IO functions
-30 VL53L0X_ERROR_INVALID_COMMAND The command is not allowed in the current device state (power down)
-40 VL53L0X_ERROR_DIVISION_BY_ZERO In the function a division by zero occurs
-50 VL53L0X_ERROR_REF_SPAD_INIT Error during reference SPAD initialization
-99 VL53L0X_ERROR_NOT_IMPLEMENTED

Position Description
1 VL53L0X_DataInit
2 VL53L0X_SetDeviceAddress
3 VL53L0X_GetDeviceInfo
4 VL53L0X_StaticInit
5 VL53L0X_PerformRefSpadManagement
6 VL53L0X_PerformRefCalibration
7 VL53L0X_SetDeviceMode
8 VL53L0X_SetLimitCheckEnable(VL53L0X_CHECKENABLE_SIGMA_FINAL_RANGE)
9 VL53L0X_SetLimitCheckEnable(VL53L0X_CHECKENABLE_SIGNAL_RATE_FINAL_RANGE)
10 VL53L0X_SetLimitCheckEnable(VL53L0X_CHECKENABLE_RANGE_IGNORE_THRESHOLD)
11 VL53L0X_SetLimitCheckValue(VL53L0X_CHECKENABLE_RANGE_IGNORE_THRESHOLD)

timing budget